  Datasheet File OCR Text:
  input parameter conditions min. typ. max. units input voltage range universal 90 264 vac 127 373 vdc input frequency 47 63 hz input filter meets en 55022 class b; fcc class b input current see model selection guide inrush current cold start, 115 vac 40.0 a pk cold start, 230 vac 90.0 safety ground leakage current 264 vac 3.5 ma output parameter conditions min. typ. max. units output voltage/current see model selection guide output voltage tolerance see note 1 ?.0 % line regulation vin = min to max ?.5 % load regulation iout = 10% to 100% ?.0 % ripple & noise (20 mhz) see note 2 ?.0 % hold-up time 115 vac 10 msec 230 vac 18 temperature coef cient ?.05 %/? short circuit protection continuous (autorecovery) over voltage protection see note 3 130 % general parameter conditions min. typ. max. units isolation voltage input to output 3,000 vac isolation resistance 500 vdc 1,000 m isolation capacitance 3,300 pf emi/rfi conducted en 55022; en 61000-3-2, -3 emc compliance electrostatic discharge (esd) iec/en 61000-4-2, -6, -8, -11 rf field susceptibility iec/en 61000-4-3 electrical fast transients/bursts on mains iec/en 61000-4-4 surge iec/en 61000-4-5 switching frequency fixed 100 khz environmental parameter conditions min. typ. max. units operating temperature range ambient 0 +25 +40 ? storage temperature range -20 +85 ? cooling free air convection (see derating curve) humidity rh, non-condensing 93 % physical size 4.00 x 2.00 x 1.10 inches (101.60 x 50.08 x 27.94 mm) weight 5.99 oz (0.170 kg) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 200 khours safety standards ul 60950, en 60950 vibration sinusoidal 15~2,000 hz, 4.0 grms, period of 60 min each along x, y & z axis single output, 100w miniature, open frame ac/dc power supplies key features: 100w output power pfc to en 61000-3-2,3 ? universal 90-264 ac input en 60950 approved (ul) miniature 2 x 4 in package meets en 55022 b meets en 61000-4 >200 khour mtbf mpo-100s series electrical speci cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com
model selection guide mechanical dimensions derating curve notes: 1. output voltage tolerance is measured at nominal input and 100% load. 2. output ripple is measured at 20 mhz bandwidth using 0.1 f and 10 f capacitors connected in parallel as close to the power supply terminals as possible. 3. these units will operate at no load without damage. for most ap- plications however, mpd recommends that a minimum load always be used. contact the factory for more information. 4. each unit includes an input fuse (250v/2a). since this fuse is not eld replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.50) micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com model number input output max output power (w) max output capacitance (f) ef ciency (%, typ) current (a) voltage (vdc) current (a) 115 vac 230 vac rated % min. mpo-100s-12 1.05 0.60 12.0 8.40 0.00 100 6,000 87 mpo-100s-15 1.05 0.60 15.0 6.70 0.00 100 6,000 87 mpo-100s-20 1.05 0.60 20.0 5.00 0.00 100 4,450 88 mpo-100s-24 1.05 0.60 24.0 4.20 0.00 100 4,450 88 mpo-100s-48 1.05 0.60 48.0 2.10 0.00 100 3,700 89 connections input connector (cn1): molex 5273-03a or equivalent (one pin removed) mating housing: molex 5195-03 or equivalent mating terminal: molex 5293 or equivalent pin function 1 ac-neutral 2 removed 3 ac-line safety ground: the mounting holes marked ?se metal standoffs should be connected to the system earth ground via metal spacers or a cable. the input side mounting hole marked ?g provides the safety earth ground for the unit. this connection should be locked to prevent possible loosening. connecting the output side mounting hole improves emi. output connector (cn2): molex 5273-04a or equivalent mating housing: molex 5195-04 or equivalent mating terminal: molex 5293 or equivalent pin function 1+v out 2+v out 3-v out 4-v out


▲Up To Search▲   

 
Price & Availability of MPO100S12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X